Journal of Turkish Clinical Biochemistry

The official publication of Turkish Society of Clinical Biochemistry

Diamond OA
No APCs
First Decision
30 Days
Indexed In
TR Dizin
Original Research
April 01, 2011
JTCB. 2011 Apr 1; 9 (1) : 015-021

Comparison of a Immunoturbidimetric and HPLC Methods in HbA1CDetermination

1 Şevket Yılmaz Eğitim ve Araştırma Hastanesi, Biyokimya, Bursa
2 Yüksek İhtisas Eğitim ve Araştırma Hastanesi, Biyokimya, Bursa

Abstract

Objective: Measurement of HbA1c is widely used in patients with diabetes mellitus as a monitor of retrospective glycemic control. Currently, more than 30 different methods are commercially available to measure HbA1c and these methods vary in the fraction of Hb measured and the interferants. The aim of this study was to study the performance of immunoturbidimetric method against the high performance liquid chromatography (HPLC) method as the reference.

Materials and Methods: Control sera were used to define within-day and between-day precision. Samples from 144 subjects were collected and HbA1c levels were determined (double-blind, paralel manner) using both systems.

Results: Intra- and the inter-assay C Vs (coefficient of variation) of assay systems were < 3% with the immunoturbidimetric method ( HbA1c values 5.1% and 8.2% ) and and < 2% with the HPLC method (HbA1c values 5.1% and 10.5%) , respectively. There was significant difference between HbA1c results measured with HPLC (8.9%±2.8) and turbidimetric immuno-inhibition (8.2%±2.8) methods (p<0.01). Accuracy was evaluated in the selected fresh sera with HbA1c levels between 5.1-17.5 %. Correlation coefficient was r=0.987 and the regression equation was [Dimension HbA1c (%) = 0.974xHPLC (%) -0.442] acceptable.

Conclusion: Although the results of immunoturbidimetric assay system is comparable to HPLC system; depending on the importance of small changes in HbA1c levels in therapy one method should be chosen for monitoring diabetic patients.

Citation

Üstündağ, Yasemin, Kağan Huysal, and Gülsevil Tarakçı. 2011. “Comparison of a Immunoturbidimetric and HPLC Methods in HbA1CDetermination”. Journal of Turkish Clinical Biochemistry 9 (1):015-021. https://turkclinbiochem.org/index.php/pub/article/view/149.

Publish with JTCB

Diamond Open Access

Fully Diamond OA with no APCs and no submission fees. Your research is freely available to readers worldwide from the day it publishes.

30-Day First Decision

Double-blind peer review from an active editorial team returns a first decision in about 30 days, keeping your manuscript moving.

Global Platform

Backed by the Turkish Society of Clinical Biochemistry, JTCB welcomes submissions from researchers worldwide and reaches an international laboratory audience.

Focused Laboratory Scope

Method validation, analyzer comparisons, reference intervals, quality indicators, preanalytical studies, and instructive clinical case reports.

Credible and Discoverable

All manuscripts publish in English and follow ICMJE and COPE guidelines, with Crossref DOIs and TR Dizin indexing ensuring global discoverability.