Journal of Turkish Clinical Biochemistry

The official publication of Turkish Society of Clinical Biochemistry

Diamond OA
No APCs
First Decision
30 Days
Indexed In
TR Dizin
Original Research
April 01, 2014
JTCB. 2014 Apr 1; 12 (1) : 001-007

Which Method is More Accurate in Patient-side Glucose Monitoring Systems?

1 İstanbul Medeniyet Üniversitesi Göztepe Eğitim Araştırma Hastanesi, İç Hastalıkları, İstanbul, Türkiye
2 İstanbul Medeniyet Üniversitesi Göztepe Eğitim Araştırma Hastanesi, Biyokimya, İstanbul, Türkiye

Abstract

Objective: Comparison of two patient-side glucometers, Accuchek Active (AC) and Optium Xceed (OP)with autoanalyzer Olympus AU 2700 (OL), which uses the reference method.

Materials and Methods: 44 patients, aged over 18, who attended emergency and internal medicine clinics at Goztepe Training and Research Hospital, were recruited fort he study. 2 cc blood was drawn from the antecubital vein and transefered to Standard tubes with EDTA. All samples were studied in each device twice, mean values were recorded.

Results: Pyrolinquinoline quinon-linked glucose dehydrogenase (GDH) enzyme using bis- (2- hydroxyethyl)- (4-hydroxyiminohexo 2,5-dieniliden)-ammonium chloride as a mediator, was superior to NAD (nicotinamide dinucleotide)-linked GDH enzyme using PQ (phenantroline quinone) as a mediator, in measuring glucose levels closer to the reference method. All measurements with hexokinase method were lower than GDH method and the difference between them showed a linear correlation with increasing glucose levels.

Conclusion: Accuracy of measurements with regards to the reference method should be the point of care in choosing patient-side glucometers. It must be kept in mind that all portable glucometers read higher levels than the reference method and this might be emphasized in education for diabetes.

Citation

Ekiz, Esra, Şermin Acar Duran, and Mihriban Ulaş. 2014. “Which Method Is More Accurate in Patient-Side Glucose Monitoring Systems?”. Journal of Turkish Clinical Biochemistry 12 (1):001-007. https://turkclinbiochem.org/index.php/pub/article/view/194.

Publish with JTCB

Diamond Open Access

Fully Diamond OA with no APCs and no submission fees. Your research is freely available to readers worldwide from the day it publishes.

30-Day First Decision

Double-blind peer review from an active editorial team returns a first decision in about 30 days, keeping your manuscript moving.

Global Platform

Backed by the Turkish Society of Clinical Biochemistry, JTCB welcomes submissions from researchers worldwide and reaches an international laboratory audience.

Focused Laboratory Scope

Method validation, analyzer comparisons, reference intervals, quality indicators, preanalytical studies, and instructive clinical case reports.

Credible and Discoverable

All manuscripts publish in English and follow ICMJE and COPE guidelines, with Crossref DOIs and TR Dizin indexing ensuring global discoverability.