Journal of Turkish Clinical Biochemistry

The official publication of Turkish Society of Clinical Biochemistry

Diamond OA
No APCs
First Decision
30 Days
Indexed In
TR Dizin
Original Research
December 01, 2015
JTCB. 2015 Dec 1; 13 (3) : 107-113

The need of urine culture requests: Can it be reduced by automated urine analyzer?

1 GOP Taksim Eğitim ve Araştırma Hastanesi, Tıbbi Biyokimya, İstanbul, Türkiye
2 Şişli Hamidiye Etfal Eğitim ve Araştırma Hastanesi, Kan Merkezi, İstanbul, Türkiye

Abstract

Purpose: Urinary tracts infections (UTI) are the most common cause of bacterial and hospital based infections. The gold standard in the diagnosis of UTI is urine culture. Patients with suspected UTI are usually requested for urinalysis simultaneously with urine culture. In general practice only 20-25 % of urine culture tests are found to be positive. In our study we assessed the need for urine culture requests by considering some urinalysis parameters on a software for iRICELL 2000 automated urine analyzer.

Material and Methods: We performed our study on 493 volunteers samples which were simultaneously requested for urinalysis together with urine culture. Samples are analyzed for both urinalysis and urine culture. The principal of the software we used was to consider the count of microscopic analyze parameters; leukocyte, bacteria, all small particles (ASP) and chemical analyze parameters; leukocyte esterase and nitrite positivity to alarm us for the further need of urine culture requests. The cut-offs of these parameters are as follows; leukocyte ≥ 5 /hpf, presence of bacteria, ASP ≥ 7000 /microliter, positivity of leukocyte esterase and nitrite. In addition to the parameters considered on this software we also assessed the protein, erytrocyte, epitelial cells which are known to be increased in UTI.

Results: We determined positive urine culture (culture (+)) results in 24.1 % of total sample. Leukocyte, ASP, eritrocyte values were statistically significant in culture (+) group comparing to culture (-) group (p=0.0001). Odds ratio values (95 % CI: Confidence Interval) for leukocyte esterase, nitrite (+), bacteria (+), leucocyte> 5 and ASP>7000 were found to be 5.63, 34.02, 8.18, 4.48, 2.17 respectively. In 91.6 % culture (+) group all 5 parameters examined were above the determined cut-offs and they were considered to be iRICELL (+). The probability of positive urine cultures in İRICELL (+) group was 6.52 times greater than İRICELL (-) group. Accepting the urine culture results as gold standard we found sensitivity 91.6 %, specifity 62 %, PPV 32 %, NPV 93 %, accuracy 50 % for iRICELL 2000 method.

Conclusion: When high sensitivity and negative predictive values of urinalysis are considered automated urinalysis can be used for negative screening by reducing the need for urine culture requests.

Citation

Ayan, Nilhan Nurlu, Ayşegül Keleş, Neval Aksoy, Nesrin Gareayaghi, and Naciye Özden Serin. 2015. “The Need of Urine Culture Requests: Can It Be Reduced by Automated Urine Analyzer?”. Journal of Turkish Clinical Biochemistry 13 (3):107-13. https://turkclinbiochem.org/index.php/pub/article/view/229.

Publish with JTCB

Diamond Open Access

Fully Diamond OA with no APCs and no submission fees. Your research is freely available to readers worldwide from the day it publishes.

30-Day First Decision

Double-blind peer review from an active editorial team returns a first decision in about 30 days, keeping your manuscript moving.

Global Platform

Backed by the Turkish Society of Clinical Biochemistry, JTCB welcomes submissions from researchers worldwide and reaches an international laboratory audience.

Focused Laboratory Scope

Method validation, analyzer comparisons, reference intervals, quality indicators, preanalytical studies, and instructive clinical case reports.

Credible and Discoverable

All manuscripts publish in English and follow ICMJE and COPE guidelines, with Crossref DOIs and TR Dizin indexing ensuring global discoverability.