Journal of Turkish Clinical Biochemistry

The official publication of Turkish Society of Clinical Biochemistry

Diamond OA
No APCs
First Decision
30 Days
Indexed In
TR Dizin
Original Research
August 01, 2016
JTCB. 2016 Aug 1; 14 (2) : 100-111

Comparison of Two Different Electrophoresis Systems in Transferrin Isoform Analysis

1 Muğla Sıtkı Koçman Üniversitesi Eğitim Araştırma Hastanesi, Tıbbi Biyokimya, MUĞLA, Türkiye
2 Dokuz Eylül Üniversitesi Tıp Fakültesi, TIıbbi Biyokimya Anabilim Dalı, İZMİR, Türkiye
3 Dokuz Eylül Üniversitesi Tıp Fakültesi, Onkoloji Enstitüsü Temel Onkoloji Anabilim Dalı, İZMİR, Türkiye

Abstract

Objective: Transferrin isoform analysis is performed for diagnosis of congenital or acquired defects in protein glycosylation. The reference method for transferrin isoform analysis is isoelectric focusing electrophoresis. The objective of this study has been to perform transferrin isoform analysis using two different electrophoresis systems in our laboratory and to compare the two systems.

Materials and Methods: The isoelectric focusing electrophoresis of transferrin isoforms was performed by "Multiphor II" ve "PhastSystem". The analytical performance was evaluated using a commercially available quality control material at two different levels. The two systems were compared with regression analysis with blood samples obtained from 40 patients.

Results: In isoelectric focusing method by "Multiphor II" system the coefficients of variation (CV) were determined to be < 3.5 % for within run (n=7) and < 7 % for between run (n=20) imprecision considering di- and tetrasialotransferrin isoforms in two levels of control material. The same values for "PhastSystem" were < 7% (n=8) and < 6% (n=10) respectively. In IEF with “PhastSystem”, disialotransferrin isoforms were determined to be 9.69% and 9.27% higher while tetrasialotransferrin isoforms were determined to be 1.33% and 2.15% higher compared to “Multiphor II” at low and high levels of control material respectively. In the regression analysis (n=40) coefficients of correlation for dive tetrasialotransferrin isoforms were determined to be 0,85 ve 0,64 respectively.

Conclusion: Transferrin isoform analysis with isoelectric focusing electrophoresis can be performed precisely with similar accuracy with both “Multiphor II” and “PhastSystem”. In routine laboratory practice “PhastSystem” may be preferred due to its speed.

Citation

Bilen, Öznur, Özlem Gürsoy Çalan, Zekiye Sultan Altun, Pınar Akan, and Canan Çoker. 2016. “Comparison of Two Different Electrophoresis Systems in Transferrin Isoform Analysis”. Journal of Turkish Clinical Biochemistry 14 (2):100-111. https://turkclinbiochem.org/index.php/pub/article/view/251.

Publish with JTCB

Diamond Open Access

Fully Diamond OA with no APCs and no submission fees. Your research is freely available to readers worldwide from the day it publishes.

30-Day First Decision

Double-blind peer review from an active editorial team returns a first decision in about 30 days, keeping your manuscript moving.

Global Platform

Backed by the Turkish Society of Clinical Biochemistry, JTCB welcomes submissions from researchers worldwide and reaches an international laboratory audience.

Focused Laboratory Scope

Method validation, analyzer comparisons, reference intervals, quality indicators, preanalytical studies, and instructive clinical case reports.

Credible and Discoverable

All manuscripts publish in English and follow ICMJE and COPE guidelines, with Crossref DOIs and TR Dizin indexing ensuring global discoverability.