Journal of Turkish Clinical Biochemistry

The official publication of Turkish Society of Clinical Biochemistry

Diamond OA
No APCs
First Decision
30 Days
Indexed In
TR Dizin
Original Research
August 01, 2018
JTCB. 2018 Aug 1; 16 (2) : 091-100

Evaluation of 25-Hydroxyvitamin D3 Measurement Uncertainty with Liquid Chromatography-Tandem Mass Spectrometry

1 Sağlık Bilimleri Üniversitesi, Okmeydanı Eğitim ve Araştırma Hastanesi, Tıbbi Biyokimya, İstanbul, Türkiye
2 Hitit Üniversitesi, Erol Olçok Eğitim ve Araştırma Hastanesi, Tıbbi Biyokimya, Çorum, Türkiye

Abstract

Purpose: The measurement uncertainty is a quantitative indicator of the quality of the test result obtained and indicates how the test results represent the actual value. For this reason, we aimed to calculate the measurement uncertainty for the 25-hydroxyvitamin D3 assay, which was analyzed by liquid chromatography-tandem mass spectrometry in our laboratory, to compare our findings with other results in the literature and to evaluate the possible effect of uncertainty value on patients' D vitamin status.

Materials and Methods: For 25-hydroxyvitamine D3 analyzed by liquid chromatography-tandem mass spectrometry, in the direction of the measurement uncertainty calculation model, which is based on the Nordest guide, standard uncertainties arising from 20 external quality controls, including 4 cycles, 5 levels per cycle, resulting from a total of 440 internal quality controls pathological and normal levels at one year, and the combined uncertainty was calculated by taking this value as a square root. Then the extended uncertainty of measurement was obtained by multiplying with the combined standard uncertainty value k factor.

Results: The intra-laboratory reproducibility was 7.44%, the bias from the laboratory was 16.01%, the bias from the measurement procedure was 0.82%, the measurement uncertainty of the bias component was 16.03%, the combined standard uncertainty was 17.67% The uncertainty of measurement was calculated as 34.64%.

Conclusions: For 25-hydroxyvitamin D3 the total allowable error is +/- 25%, as a result of our study; The expanded measurement uncertainty value for 25-hydroxyvitamin D3 was found to be high. Targeted solutions should be sought to limit possible errors in order to reduce this value to less than 25%. Adding measurement uncertainty to the patient's outcome will increase confidence in the physician's strength and laboratory results at the point of clinical decision-making.

Citation

Basat, Burcu, Müberra Vardar, Okan Dikker, and Mustafa Şahin. 2018. “Evaluation of 25-Hydroxyvitamin D3 Measurement Uncertainty With Liquid Chromatography-Tandem Mass Spectrometry”. Journal of Turkish Clinical Biochemistry 16 (2):091-100. https://turkclinbiochem.org/index.php/pub/article/view/316.

Publish with JTCB

Diamond Open Access

Fully Diamond OA with no APCs and no submission fees. Your research is freely available to readers worldwide from the day it publishes.

30-Day First Decision

Double-blind peer review from an active editorial team returns a first decision in about 30 days, keeping your manuscript moving.

Global Platform

Backed by the Turkish Society of Clinical Biochemistry, JTCB welcomes submissions from researchers worldwide and reaches an international laboratory audience.

Focused Laboratory Scope

Method validation, analyzer comparisons, reference intervals, quality indicators, preanalytical studies, and instructive clinical case reports.

Credible and Discoverable

All manuscripts publish in English and follow ICMJE and COPE guidelines, with Crossref DOIs and TR Dizin indexing ensuring global discoverability.