Journal of Turkish Clinical Biochemistry

The official publication of Turkish Society of Clinical Biochemistry

Diamond OA
No APCs
First Decision
30 Days
Indexed In
TR Dizin
Original Research
August 01, 2019
JTCB. 2019 Aug 1; 17 (2) : 085-094

A Simple, Sensitive and Rapid HPLC-UV Method for the Determination of 25(OH)D and Comparison of the İmmunoassay Method

1 Balıkesir Üniversitesi Tıp Fakültesi Biyokimya Anabilim Dalı

Abstract

Aim: Vitamin D deficiency is a common public health problem in our country. It is possible to find data reaching 90% in studies about determining deficiency prevalence. In recent years, this deficiency has been attracted the attention of the press and has directed people to a search for blood level monitoring. For these reasons, there are also serious increases in the number of vitamin D levels analyses in laboratories. Due to the high measurement costs per patient, it is also one of the most important laboratory expenses. It is aimed to develop an simple, sensitive and rapid in-house analysis method in order to reduce laboratory costs and to determine 25(OH)D2 and D3 forms separately.

Material and Methods: Ultimate 3000HPLC-UV (Dionex, Germany) was used in the development of the method. Architect 25(OH)D kit (Abbott Diagnostic, USA) were used for method comparison study. Validation studies were performed using CLSI guidelines(EP5-A2,EP6-A,EP9-A2). Accuracy was evaluated using Certified Reference Material (UME CRM 1308). For chromatographic separation, reverse phase 150mmX4.6mm,(3.0 μm) ODS-1 (Thermo Scientific,USA) analytical column was used.

Results: Within run, between run and between day precisions (%CV) for 18.9ng/mL 25(OH)D3 were 2.6%, 2.7%, 6.3% and for 57.4ng/mL were 1.8%, 1.8% and 4.8% respectively. For 25(OH)D3, the LOD was 0.7ng/mL and the LOQ was 2.1ng/mL. Correlation between HPLC-UV and Abbott Architect systems was evaluated by Passing Bablok regression analysis (y=0,89x+1,81).

Conclusion: The compatibility between HPLC-UV and Abbott Architect suggests that both methods can be preferred. However,each laboratory should decide according to the their conditions in which the method is selected for the determination of 25(OH)D. Because in such cases where test performances are very similar. The number of patients, experienced staff presence and cost-determining parameters will be more prominent in the selection of methods,

Citation

Baykan, Özgür. 2019. “A Simple, Sensitive and Rapid HPLC-UV Method for the Determination of 25(OH)D and Comparison of the İmmunoassay Method”. Journal of Turkish Clinical Biochemistry 17 (2):085-094. https://turkclinbiochem.org/index.php/pub/article/view/346.

Publish with JTCB

Diamond Open Access

Fully Diamond OA with no APCs and no submission fees. Your research is freely available to readers worldwide from the day it publishes.

30-Day First Decision

Double-blind peer review from an active editorial team returns a first decision in about 30 days, keeping your manuscript moving.

Global Platform

Backed by the Turkish Society of Clinical Biochemistry, JTCB welcomes submissions from researchers worldwide and reaches an international laboratory audience.

Focused Laboratory Scope

Method validation, analyzer comparisons, reference intervals, quality indicators, preanalytical studies, and instructive clinical case reports.

Credible and Discoverable

All manuscripts publish in English and follow ICMJE and COPE guidelines, with Crossref DOIs and TR Dizin indexing ensuring global discoverability.