Journal of Turkish Clinical Biochemistry

The official publication of Turkish Society of Clinical Biochemistry

Diamond OA
No APCs
First Decision
30 Days
Indexed In
TR Dizin
Original Research
April 01, 2020
JTCB. 2020 Apr 1; 18 (1) : 026-032

Effect of hs Troponin I Measurement Uncertainty on Interpretation at Clinical Decision Limits

1 İzmir Kemalpaşa Devlet Hastanesi, Tıbbi Biyokimya, İzmir, Türkiye

Abstract

Aim: The aim of this study was to calculate the uncertainty of the hs-cTn I test in which the clinical decision limit value was important and to evaluate the possible effect of the calculated measurement uncertainty for the test result interpretation at the clinical decision limits.

Material and Methods: Measurement uncertainty was calculated according to Nordtest technical report 537. The clinical decision limits of hs-cTnI were 2 ng/L, 6 ng/L, 19 ng/L and 100 ng/L. Lower and upper limit values of hs-cTnI test results reported by our laboratory between May 1 - October 31 2018 were calculated according to uncertainty value. When the hs-cTn I test results are reported together with the lower and upper limit values according to the uncertainty value, the number and percentage of test results that can be interpreted differently in the clinical decision limits are determined.

Results: The uncertainty of within-laboratory reproducibility (uRW) value of hs-cTn I test was 4.89% and the uncertainty component from the certified or nominal value (uCref) was 3.88%. The measurement uncertainty (95% confidence interval) of hs-cTn I was estimated to be 14.02%. The number of hs-cTn I test results analysed for suspected myocardial infarction was 2299. When the lower and upper limit values of hs-cTn I results are added to the laboratory result report according to the calculated uncertainty value, the total number of results that can be interpreted differently in the clinical decision limits is 358 (15.6%). As a result of providing uncertainty value information in the laboratory results report, we determined that 7.35% of the results reported below the decision limits can be interpreted above the decision limit and 8.22% of the results reported above the decision limits can be interpreted as below the decision limits.

Conclusion: Reporting uncertainty of measurement affects the clinical decision process. We believe that our study, in which we evaluate possible decision changes for reported results with measurement uncertainty data, supports this view.

Citation

Zorbozan, Nergiz. 2020. “Effect of Hs Troponin I Measurement Uncertainty on Interpretation at Clinical Decision Limits”. Journal of Turkish Clinical Biochemistry 18 (1):026-032. https://turkclinbiochem.org/index.php/pub/article/view/360.

Publish with JTCB

Diamond Open Access

Fully Diamond OA with no APCs and no submission fees. Your research is freely available to readers worldwide from the day it publishes.

30-Day First Decision

Double-blind peer review from an active editorial team returns a first decision in about 30 days, keeping your manuscript moving.

Global Platform

Backed by the Turkish Society of Clinical Biochemistry, JTCB welcomes submissions from researchers worldwide and reaches an international laboratory audience.

Focused Laboratory Scope

Method validation, analyzer comparisons, reference intervals, quality indicators, preanalytical studies, and instructive clinical case reports.

Credible and Discoverable

All manuscripts publish in English and follow ICMJE and COPE guidelines, with Crossref DOIs and TR Dizin indexing ensuring global discoverability.