Journal of Turkish Clinical Biochemistry

The official publication of Turkish Society of Clinical Biochemistry

Diamond OA
No APCs
First Decision
30 Days
Indexed In
TR Dizin
Original Research
August 01, 2022
JTCB. 2022 Aug 1; 20 (2) : 083-090
98 121
PDF

The Need for Assay Harmonization: Carbohydrate Antigen 19-9 (CA 19-9) Assay Example

1 Dışkapı Yıldırım Beyazıt Eğitim ve Araştırma Hastanesi, Tıbbi Biyokimya, Ankara, Türkiye

Abstract

Objectives: The carbohydrate antigen 19-9 assay is a widely used biomarker as a complement to other tests in the detection and follow-up of pancreatic, bile duct and colon cancer in high-risk individuals. The CA 19-9 assays often give different results with different methods. This study intended to characterize the harmonization problem in CA 19-9 assays using results obtained through external quality assessment.

Material and Methods: According to the 2018-External Quality Assessment program by the Randox International Quality Assessment Scheme, pooled serum specimens involving three levels of CA19-9 were analyzed. In addition, the results of four assays which are Abbott Architect, Beckman Access DXI600/800, Roche Cobas 6000/8000, and Siemens Advia Centaur XP/XPT/Classic were contrasted.

Results: Data from External Quality Assessment schemes demonstrate significant variation in CA 19-9 assay results obtained for the same specimen using different assays. The mean CA 19-9 evaluation of the peer groups differed for all four systems, and the interlaboratory CVs also varied. Generally, the highest peer groups mean values were gathered by employing the Abbott Architect system, which was followed by Siemens Centaur XP/XPT/Classic, while the lowest means were acquired utilizing the Roche Cobas system. Serum CA 19-9 assays also show a wide range in CV, which vary from 4.5-10.1%.

Conclusion: According to our findings, the harmonization of the CA 19-9 results obtained from four immunoassays have not been achieved yet. Systematic differences(different antibodies etc.) are still present among the most popular commercial methods for CA 19-9 measurement and may produce some difficulties in interpreting laboratory test results. Consequently, it is suggested that the assay or method used to identify CA 19-9 concentrations should be included in the laboratory result report.

Citation

Ucar, Fatma, Seyda Ozdemir, Gulfer Ozturk, and Ali Yalcindag. 2022. “The Need for Assay Harmonization: Carbohydrate Antigen 19-9 (CA 19-9) Assay Example”. Journal of Turkish Clinical Biochemistry 20 (2):083-090. https://turkclinbiochem.org/index.php/pub/article/view/428.

Publish with JTCB

Diamond Open Access

Fully Diamond OA with no APCs and no submission fees. Your research is freely available to readers worldwide from the day it publishes.

30-Day First Decision

Double-blind peer review from an active editorial team returns a first decision in about 30 days, keeping your manuscript moving.

Global Platform

Backed by the Turkish Society of Clinical Biochemistry, JTCB welcomes submissions from researchers worldwide and reaches an international laboratory audience.

Focused Laboratory Scope

Method validation, analyzer comparisons, reference intervals, quality indicators, preanalytical studies, and instructive clinical case reports.

Credible and Discoverable

All manuscripts publish in English and follow ICMJE and COPE guidelines, with Crossref DOIs and TR Dizin indexing ensuring global discoverability.