Journal of Turkish Clinical Biochemistry

The official publication of Turkish Society of Clinical Biochemistry

Diamond OA
No APCs
First Decision
30 Days
Indexed In
TR Dizin
Original Research
August 01, 2023
JTCB. 2023 Aug 1; 21 (2) : 102-109
DOI 10.56615/tkbd.2023.13
84 122
PDF

Discrepancy in chemical and microscopic urinalysis: Looking from a laboratory perspective

1 Recep Tayyip Erdoğan Üniversitesi Rize Eğitim ve Araştırma Hastanesi, Tıbbi Biyokimya Anabilim Dalı, Rize, Türkiye

Abstract

Objective: The discrepancy between chemical and microscopic urine examination makes it demanding to interpret the results. We aimed to evaluate the laboratory personnels effect on the consistency between chemical and microscopic urine examination results.

Material and Methods: The urinalysis results of a tertiary hospitals core and supervised laboratory between 2019 and 2020 were evaluated retrospectively. The consistency between chemical and microscopic urine examination and laboratory personnels effect on this compliance was examined by correlation and measurement of agreement analysis.

Results: The core laboratory had higher consistency in erythrocyte count and blood, leukocyte count and leukocyte esterase. Accordingly, we determined that a yeast cell count of >30 significantly reduced the conformity between blood and erythrocyte counts in the supervised laboratory. The correlation between erythrocyte count and blood increased when controlling for yeast cell count for supervised and core laboratory.

Conclusion: Laboratory personnel significantly affect the consistency between automated urinalysis chemical and microscopic examination results. For the reliability of the results, it is essential to reduce the unnecessary workload of laboratory personnel and increase the time they will spend on specific tests.

Citation

Şen, Bayram, and Medeni Arpa. 2023. “Discrepancy in Chemical and Microscopic Urinalysis: Looking from a Laboratory Perspective”. Journal of Turkish Clinical Biochemistry 21 (2):102-9. https://doi.org/10.56615/tkbd.2023.13.

Publish with JTCB

Diamond Open Access

Fully Diamond OA with no APCs and no submission fees. Your research is freely available to readers worldwide from the day it publishes.

30-Day First Decision

Double-blind peer review from an active editorial team returns a first decision in about 30 days, keeping your manuscript moving.

Global Platform

Backed by the Turkish Society of Clinical Biochemistry, JTCB welcomes submissions from researchers worldwide and reaches an international laboratory audience.

Focused Laboratory Scope

Method validation, analyzer comparisons, reference intervals, quality indicators, preanalytical studies, and instructive clinical case reports.

Credible and Discoverable

All manuscripts publish in English and follow ICMJE and COPE guidelines, with Crossref DOIs and TR Dizin indexing ensuring global discoverability.