Low HbA1c Measurement Inconsistent with Blood Sugar: Evans Syndrome

1 Zonguldak Bülent Ecevit Universitesi Tıp Fakültesi, Tıbbi Biyokimya, Zonguldak, Türkiye
2 Zonguldak Bülent Ecevit Universitesi Tıp Fakültesi, Endokrinoloji, Zonguldak, Türkiye
3 Zonguldak Bülent Ecevit Universitesi Tıp Fakültesi, Hematoloji, Zonguldak, Türkiye

Abstract

Aim: We aimed to demonstrate the interference in Hemoglobin A1c (HbA1c) testing in a patient diagnosed with Evans syndrome, a rare condition characterized by autoimmune hemolytic anemia.

Case: A patient who presented to our laboratory for biochemical evaluation was found to have an HbA1c level below the detection limit (<3%) when measured by high-performance liquid chromatography (HPLC). Since the HbA1c result was inconsistent with the patients previous blood glucose levels, an alternative method was employed to rule out potential analytical interference. The HbA1c level measured by the immunoturbidimetric method was also below the detection limit (<4%). A detailed review of the patients clinical file revealed a diagnosis of Evans syndrome, characterized by autoimmune hemolytic anemia.Result:It should be noted that in patients with autoimmune hemolytic anemia, falsely low HbA1c results may occur regardless of the analytical method used.

Citation

Güven, Berrak, Ferhan Adıbelli, Taner Bayraktaroğlu, and Birsen Sahip Yesiralioglu. 2025. “Low HbA1c Measurement Inconsistent With Blood Sugar: Evans Syndrome”. Journal of Turkish Clinical Biochemistry 23 (2):079-083. https://doi.org/10.56615/tkbd.2025.09.

Publish with JTCB

Diamond Open Access

Fully Diamond OA with no APCs and no submission fees. Your research is freely available to readers worldwide from the day it publishes.

30-Day First Decision

Double-blind peer review from an active editorial team returns a first decision in about 30 days, keeping your manuscript moving.

Global Platform

Backed by the Turkish Society of Clinical Biochemistry, JTCB welcomes submissions from researchers worldwide and reaches an international laboratory audience.

Focused Laboratory Scope

Method validation, analyzer comparisons, reference intervals, quality indicators, preanalytical studies, and instructive clinical case reports.

Credible and Discoverable

All manuscripts publish in English and follow ICMJE and COPE guidelines, with Crossref DOIs and TR Dizin indexing ensuring global discoverability.