Buket Kın Tekçe, Hikmet Tekçe
Objective: Intact parathyroid hormone is used for diagnostic follow up in chronic kidney disease
mineral bone disorder. Studies have shown that there was considerable bias between methods intact
parathyroid hormone assays. This study has investigated the variation between...
Journal of Turkish Clinical Biochemistry
•
2015-04-01
Kübranur Ünal
Objective: The aim of this study, was to determine whether the Troponin I and CK-MB test results
obtained from our laboratory meet the acceptable quality standards.
Material and Methods: Total %CV of troponin I and CK-MB was obtained from internal...
Journal of Turkish Clinical Biochemistry
•
2018-04-01
Tülay Çevlik, Goncagül Haklar
Aim: Six Sigma is a quality management tool that helps continuously monitor and improve the performance of the tests in the clinical laboratory. The quality goal index (QGI) ratio represents the state of meeting the respective quality targets of both bias and precision. The...
Journal of Turkish Clinical Biochemistry
•
2023-04-01
•
DOI: 10.56615/tkbd.2023.03
Burcu Basat, Müberra Vardar, Okan Dikker, Mustafa Şahin
Purpose: The measurement uncertainty is a quantitative indicator of the quality of the test result
obtained and indicates how the test results represent the actual value. For this reason, we aimed to
calculate the measurement uncertainty for the 25-hydroxyvitamin D3 assay,...
Journal of Turkish Clinical Biochemistry
•
2018-08-01
Tuğba Öncel, Mehmet Hicri Köseoğlu, Hayat Özkanay Yörük, Ayşenur Atay, Leyla Demir, Figen Narin
Aim: Sigmametric methodology is used as a quality management tool that predicts variables can be
controlled and targets zero error.In this study, sigmametrics were calculated for some fertility function
tests to pick the suitable quality control tools and approach for...
Journal of Turkish Clinical Biochemistry
•
2021-04-01
Pelin Kulan, Ahmet Rıza Uras, Sedef Delibaş, Mustafa Durmuşcan, Sembol Yıldırmak
Aim: Method evaluation studies should be carried out for every new method planned to be used in
laboratories. The aim of this study is to determine the analytical performance of the immunoassay
method used for determining of plasma 25-hydroxy vitamin D levels and also to...
Journal of Turkish Clinical Biochemistry
•
2016-12-01
Şeniz Korkmaz
Aim: In this study, we aimed to evaluate the analytical process performance of clinical biochemistry
parameters by six sigma method and to make the necessary arrangements according to the obtained
results in our laboratory.
Material and Methods: In...
Journal of Turkish Clinical Biochemistry
•
2019-12-01
Gökhan Çakırca, Tülin Yazıcı
Aim: Six sigma is a quality management tool used to evaluate analytical process performance. We
evaluated the performance of biochemical and immunological tests on a Roche Cobas 8000 device in
our laboratory using sigma metrics.
Materials and Methods:...
Journal of Turkish Clinical Biochemistry
•
2019-08-01
Hale Aral, Berrin Berçik İnal, Murat Usta, Pınar Tonbaklar Bilgi, Ömer Emecen, Mustafa Şahin, Güvenç Güvenen
Objective: We aimed to investigate the possible differences between the analytical assay and estimation with Friedewald formula of LDL cholesterol in patients divided into subgroups according to direct LDL cholesterol, triglyceride, total cholesterol levels,...
Journal of Turkish Clinical Biochemistry
•
2008-08-01
Şerif Ercan
Background: The evaluation of pre-analytical, analytical and post-analytical phases is very important to
obtain accurate, price and comparable results. Quality indicators are generally used to evaluate these
processes. The present study aimed to evaluate the analytical phase...
Journal of Turkish Clinical Biochemistry
•
2015-08-01
Nuri Orhan, Hayriye Ak Yıldırım, Hatice Yüksel, Özlem Yavuz, Ramazan Memişoğullar
Objective: The cardiac troponins are sensitive and specific biochemical markers of myocardial
damage. It has been suggested that hemolysis causes interference in the immunometric cardiac
troponin assay. The current study aimed to determine the significance of hemolysis as an...
Journal of Turkish Clinical Biochemistry
•
2010-04-01
Fatma Demet İnce, Hamit Yaşar Ellidağ, Merve Zeytinli, Ramazan Avcı, Defne Özbek, Elif Merve Arı
Purpose: The measurement of serum ferritin is used as a reliable and noninvasive method for the
monitoring of iron stores. There are many different methods for the ferritin measurement. However, the
immunoturbidimetric method that having the less cost and possibility of the...
Journal of Turkish Clinical Biochemistry
•
2016-04-01
Özben Özden Işıklar, Evin Kocatürk, Sercan Erol, Elif Nur Arıkan Bakım, Muzaffer Bilgin, Hüseyin Kayadibi, İ.Özkan Alataş
Objective: This study aimed to evaluate the agreement between albumin measurements obtained via capillary zone electrophoresis (CZE) and bromocresol green (BCG) methods and to determine their interchangeability in clinical practice. Additionally, it explored how these results...
Journal of Turkish Clinical Biochemistry
•
2024-12-01
•
DOI: 10.56615/tkbd.2024.15
Giray Bozkaya, Kaan Kuzu, Ali Rıza Şişman
Aim: Panic value refers to a laboratory test result that is life-threatening and requires immediate corrective action by the physician. Although there is no recommendation to re-run the panic-valued test, some laboratory specialists report the result after repeating the test....
Journal of Turkish Clinical Biochemistry
•
2023-12-01
•
DOI: 10.56615/tkbd.2023.16
Şerif Ercan, Mahmut Çakır
Objective: The use of different types of analyzers and samples lead to obtaining different test results.
This study aimed to investigate whether the test results yielded by conventional blood gas analyzer
(cBGA) are considered interchangeable with those produced by...
Journal of Turkish Clinical Biochemistry
•
2018-04-01
Fatıma Betül Tuncer, Erdem Çokluk, Mehmet Ramazan Şekeroğlu, Fatma Özdemir, Meltem Boz
Objective: The aim of this study is to investigate the compatibility of bicarbonate (HCO3-) levels
measured by blood gas meter in serum autoanalyser.
Materials and Methods: In the study, serum bicarbonate and blood gas bicarbonate levels of 186...
Journal of Turkish Clinical Biochemistry
•
2019-12-01
Giray Bozkaya, Öznur Asil, Kaan Kuzu
Aim: Measurement uncertainty provides information about the limits at which the measured value may vary as a result of random effects in a biochemical measurement. It is a quantitative indicator of the quality of the result obtained and allows us to estimate the extent to...
Journal of Turkish Clinical Biochemistry
•
2023-04-01
•
DOI: 10.56615/tkbd.2023.01
Sema Nur Ayyıldız
Objective: Test analyses in laboratories must leave neither clinician nor patient in doubt. Measurement
uncertainty must therefore be studied for all tests in laboratories. The aim of this study was to calculate
the measurement uncertainty of the hormone...
Journal of Turkish Clinical Biochemistry
•
2016-08-01
Mehmet Akif Bildirici
Objective: To compare the analytical performance of 2 immunoturbidimetric C-reactive protein (CRP) reagents using the same automated analyzer and to evaluate whether an alternative reagent provides clinically acceptable results.
Methods: This...
Journal of Turkish Clinical Biochemistry
•
2026-08-25
•
DOI: 10.65717/jtcb.2026.26023
Dilek İren Emekli, Kenan Güçlü, Gamze Turna, Bilal İlanbey, Rukiye Nar, Esin Avcı Çiçek
Objective: Analytical reliability of clinical laboratories may be obtained by internal quality control,
external quality control by analyzing the data with statistical methods. In Six Sigma Methodology, which
is one of these methods, the analytical performance of the tests...
Journal of Turkish Clinical Biochemistry
•
2016-08-01
Seçkin Özgür Tekeli, Güzin Aykal, Feyza Yağmur Tekeli, Nur Benil Yabacı
Aim: This study aimed to evaluate the performance characteristics of preliminary coagulation tests on the Sysmex CS-5100 coagulation autoanalyzer and compare it with the ACL Top 700 autoanalyzer. Both analyzers were assessed for their ability to measure prothrombin time (PT),...
Journal of Turkish Clinical Biochemistry
•
2025-12-01
•
DOI: 10.56615/tkbd.2025.14
Esra Fırat Oğuz, Fatma Meriç Yılmaz, Turan Turhan, Canan Topçuoğlu, Müjgan Ercan Karadağ
Aim: Cross-reactivity in immunological techniques varies and the frequency depends on the population
of the study, technique for detecting the reaction and researchers method. In this study our aim was to
evaluate the cross-reactivity in thyroid function tests.
...
Journal of Turkish Clinical Biochemistry
•
2021-04-01
Kübra Nazmiye Öztürk, Nahide Ekici Günay, Derya Koçer
Aim: Six Sigma methodology used in clinical laboratories is a quality management tool based on statistical calculations, focusing on process variables and providing information about process performance. In this study, we aimed to evaluate the analytical process performances...
Journal of Turkish Clinical Biochemistry
•
2024-08-01
•
DOI: 10.56615/tkbd.2024.09
Inanc Karakoyun, Fatma Demet Arslan, Selin Onur, Yasemin Kilic Ozturk, Hulya Parildar, Banu Isbilen Basok
Aim: In this study, we compared 3 different clot-activator gel tubes to a glass reference tube and
evaluated the effect of storage time on 30 different biochemical analytes.
Material and Methods: Blood samples were collected in 4 types of tubes: an...
Journal of Turkish Clinical Biochemistry
•
2020-08-01
Sevim Eşmedere Eren, Banu Çaycı, Gökçe Atikeler, Özlem Gülbahar, Hatice Paşaoğlu
Objective: If a new analyzer in the laboratories is considered to be used, method comparison should be done. Two analyzers should be compared in order to evaluate accuracy of the new analyzer. In our study, we aimed to compare the performance of new coagulation analyzer with...
Journal of Turkish Clinical Biochemistry
•
2013-04-01